Dynamic Texture Analyzer Addresses Poor Sensory Panel / Instrument Correlation
Annual Meeting of the Institute of Food Technologists, Book of Abstracts, 44, (1996)
J.C. CONTI, E.R. Strope, D.J. Rohde, L.D. Spence
Dynatek Dalta Scientific Instruments, PO Box 254, Galena, MO 65656
Texture is an important property of foods that is sometimes
difficult to quantitate. Although sensory panels can be trained to
evaluate the various textural properties of a new or modified food,
they also suffer from a degree of unsurity associated with the
aboption of parameters that are presented during training. It
would be beneficial to food scientists and technologists to be able
to, at least at the beginning of a food development cycle, to more
reproducibly and precisely quantitate the textural properties of
foods so that the evaluation by the sensory panels can be utilized
closer to the end of the development cycle.
Texture profile analysis recognized the fact the texture was a
multi-parameter attribute that could possible be quantitated using
a set of classifications first introduced by Szczesniak (1963). In
that classification the mechanical aspects of texture included the
primary characteristics of hardness, cohesiveness, springiness,
adhesiveness and viscosity while the secondary characteristics
included brittleness, chewiness and gumminess. Chewiness is the
energy required to masticate solid food to a state of readiness for
swallowing, somewhat subjective. Gumminess is the energy
required to disintegrate a semi-solid food to a readiness for
swallowing, again, rather subjective. Adding to the confusion,
chewiness was defined as the product of hardness X cohesiveness X
springiness while gumminess was a product of hardness X
cohesivshermanis relationship, one who is not familiar with the
field might conclude that chewiness was actually the product of
gumminess X springiness.
This confusion has been present in many publication in literature,
see Born (1978). And was addressed in recent letters Szczesniak
(1995).
In addition to this confusion of definitions there also has been
reported many examples where mechanical analysis of texture
does not agree with the results of sensory panels. Eves (1988);
Jack (1993); Szczesniak (1987); Lockhanie (1991); Kolioie and
Sherman (1996); Bryant et a1 (1995) and Raphaelides (1995). An
evaluation of these papers and the testing techniques and
parameters that were used to generate the mechanical texture
variables lead to two conclusions. First, many of the
measurements that were made that resulted in a lack of
correlation with sensory panels were made on instruments that
were not sensitive enough to differentiate small changes in
properties that were in fact differentiable by the sensory panel.
Secondly, certain of the parameters that were being evaluated
were perhaps being measured using mechanical properties that did
not infact properly reflect the characteristics that were being
looked for. For example, machine evaluated cohesiveness is defined
as the ratio of the positive area (load versus sample dimension)
during second compression of that to the first compression. Where
as cohesiveness from the sensory panel is defined as the degrees to
which the chief sample deformed before rupturing. Clearly a test
that relates to the sensory panels evaluation of cohesiveness could
easily be adopted with the appropriate instrumentation. Another
example is springiness. The mechanical evaluated parameter
defines it as the height that the food recovers during the time that
elapsed between the end of the first compression cycle and the
start of the second cycle. Where as with the sensory panel, it's
defined as the bouncing back property of sample through several
consecutive bites. Again, an instrument that could cyclically
evaluate the elastic or viscoelastic properties through several
cycles would more likely correlate the mechanical testing to the
sensory panels evaluation. Other examples of the lack of
coordination between the definition of instrument evaluated
texture versus sensory panel evaluated texture include the fact
that hardness is testing with a molar on the panel and not with an
instrument, and the fact that there is no adhesiveness or
stickiness at all tested with the instrumentation.
We have developed a dynamic texture analyzer that addresses
most of the issues that we feel make it difficult to generate
information that correlates between panel and instrument. This
analyzer is unique in that it is electromagnetically actuated and
computer controlled, As a result, any complex wave form can be
programmed into the computer which will then run the instrument
such that the technician can define the exact load versus time or
dimension versus time parameters that are of interest. In
addition, the instrument can work in the compression and tensile
mode simultaneously so that for example hardness and
adhesiveness can be evaluated each cycle. In addition, because of
the precession of the instrument with respect to the control of
experimental parameters, it can be used effectively in the cyclic
testing manner.
Because this device is computer controlled and monitored, other
parameters can be automatically calculated that give a somewhat
better understanding of certain properties of food. For example, by
defining the compressive properties of a material that is ready for
swallowing, one can program the instrument to repeatedly chew
food until the desired compressive parameters are obtained. By
monitoring the total energy required to attain these parameters
one can then get a useful evaluation of a chewiness parameter. By
carrying out this testing in a flexible and resilient testing chamber
that returns the food products to the path of the VirtualTooth, one
can also add different amounts of water or other lubricants to the
experimental chamber to evaluate how the incorporation of these
solvents or lubricants impact the chewiness of the sample.
Gumminess is another parameter that can be addressed by
experimental techniques that are similar to those used in the
chewiness discussion.
Another very useful characteristic of this VirtualChewer is that
the central computer can run up to eight independent stations. As
a result, those tests that may require several chews that take a
great deal of time because of the slowness of the rate of chewing,
can be done much more timely and cost effectively by having
several stations going independently.
In addition to the precise control of the experimental parameters
that comes from electrical magnetic actuation, and the ease of
handling data from an instrument that automatically collects,
stores, and analysis the data, and additional benefit is that this
instrument can be outfitted with a number of load cells and
displacement transducers to cover a wide range of capabilities. At
its most sensitive set up the instruments can measure loads down
to 23mg and displacements down to 1 micron. Although this seems
somewhat small with respect to the kinds of measurements that
are made in food technolosis, it in fact allows for the generation of
data that in fact becomes very useful, for example, testing true
hardness, stickiness or springiness.
The Dynamic Texture Analyzer has allowed us to generate
information in a more comprehensive and quantitatively and
reliable manner which should lead to a situation were food
technologists can more easily and effectively develop foods with
more agreeable texture characteristics.